Free MEP and Electrical Details

Mechanical, electrical and plumbing details: water and sewer lines, pump stations, power, lighting and controls. Every file here is public domain: open it in your browser, then download it and use it for anything.

1814 drawings · DWG, DXF, PDF, SVG, DWF and more · public domain

219 drawings in MEP & electrical · Clear all

  • Electrical single-line diagram (Visio)vsdxOpen the drawing
    Electrical single-line diagram (Visio)

    Single-line diagram of an office building supply: transformer, main breaker, busbar, eight feeders, generator and ATS.

  • HVAC maintenance checklist (Word)docxOpen the drawing
    HVAC maintenance checklist (Word)

    Quarterly preventive maintenance checklist for rooftop HVAC units, with task tables for filters, refrigeration, heating and controls.

  • Wall hung WC plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Wall hung WC plan - Plumbing and HVAC CAD Symbol

    Original wall hung wc plan, 590 x 675 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 590 x 675 x 0 mm. Nominal size: 590 x 675 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Wall extractor fan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Wall extractor fan - Plumbing and HVAC CAD Symbol

    Original wall extractor fan, 500 x 500 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 500 x 500 x 0 mm. Nominal size: 500 x 500 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Wall basin plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Wall basin plan - Plumbing and HVAC CAD Symbol

    Original wall basin plan, 600 x 480 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 480 x 0 mm. Nominal size: 600 x 480 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Volume control damper - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Volume control damper - Plumbing and HVAC CAD Symbol

    Original volume control damper, 600 x 530 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 530 x 0 mm. Nominal size: 600 x 530 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Utility sink plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Utility sink plan - Plumbing and HVAC CAD Symbol

    Original utility sink plan, 600 x 550 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 550 x 0 mm. Nominal size: 600 x 550 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Urinal plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Urinal plan - Plumbing and HVAC CAD Symbol

    Original urinal plan, 450 x 500 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 450 x 500 x 0 mm. Nominal size: 450 x 500 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Thermostat - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Thermostat - Plumbing and HVAC CAD Symbol

    Original thermostat, 300 x 300 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 300 x 300 x 0 mm. Nominal size: 300 x 300 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Strainer symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Strainer symbol - Plumbing and HVAC CAD Symbol

    Original strainer symbol, 700 x 400 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 700 x 330 x 0 mm. Nominal size: 700 x 400 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Square supply diffuser - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Square supply diffuser - Plumbing and HVAC CAD Symbol

    Original square supply diffuser, 600 x 600 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 600 x 0 mm. Nominal size: 600 x 600 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Shower tray plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Shower tray plan - Plumbing and HVAC CAD Symbol

    Original shower tray plan, 900 x 900 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 900 x 900 x 0 mm. Nominal size: 900 x 900 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Round supply diffuser - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Round supply diffuser - Plumbing and HVAC CAD Symbol

    Original round supply diffuser, 560 x 560 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 560 x 560 x 0 mm. Nominal size: 560 x 560 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Return air grille - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Return air grille - Plumbing and HVAC CAD Symbol

    Original return air grille, 600 x 300 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 300 x 0 mm. Nominal size: 600 x 300 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pressure reducing valve symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pressure reducing valve symbol - Plumbing and HVAC CAD Symbol

    Original pressure reducing valve symbol, 700 x 470 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 700 x 470 x 0 mm. Nominal size: 700 x 470 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Plumbing symbols A3 sheet - CAD CollectiondxfOpen the drawing
    Plumbing symbols A3 sheet - CAD Collection

    A3 sheet with 22 individually named original CAD blocks and real sizes; DXF retains each block's 1:1 millimetre geometry. Print PDF or SVG at 1:30. Overall 12 x 8.3 x 0 m. Nominal size: A3. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pipe tee symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pipe tee symbol - Plumbing and HVAC CAD Symbol

    Original pipe tee symbol, 700 x 440 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 700 x 440 x 0 mm. Nominal size: 700 x 440 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pipe reducer symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pipe reducer symbol - Plumbing and HVAC CAD Symbol

    Original pipe reducer symbol, 700 x 240 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 700 x 240 x 0 mm. Nominal size: 700 x 240 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pipe flange symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pipe flange symbol - Plumbing and HVAC CAD Symbol

    Original pipe flange symbol, 700 x 360 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 700 x 360 x 0 mm. Nominal size: 700 x 360 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pipe elbow symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pipe elbow symbol - Plumbing and HVAC CAD Symbol

    Original pipe elbow symbol, 440 x 440 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 440 x 440 x 0 mm. Nominal size: 440 x 440 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pipe cap symbol - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pipe cap symbol - Plumbing and HVAC CAD Symbol

    Original pipe cap symbol, 350 x 180 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 385 x 180 x 0 mm. Nominal size: 350 x 180 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Pedestal basin plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Pedestal basin plan - Plumbing and HVAC CAD Symbol

    Original pedestal basin plan, 600 x 480 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 600 x 480 x 0 mm. Nominal size: 600 x 480 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Linear slot diffuser - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Linear slot diffuser - Plumbing and HVAC CAD Symbol

    Original linear slot diffuser, 1200 x 120 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 1200 x 120 x 0 mm. Nominal size: 1200 x 120 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

  • Kitchen sink plan - Plumbing and HVAC CAD SymboldxfOpen the drawing
    Kitchen sink plan - Plumbing and HVAC CAD Symbol

    Original kitchen sink plan, 800 x 480 mm graphic envelope. DXF is 1:1 in millimetres with a clean insertion origin; named A3 PDF/SVG proof included. Overall 800 x 480 x 0 mm. Nominal size: 800 x 480 mm. DXF drawing at 1:1 in millimeters with named layers; opens in AutoCAD, LibreCAD, Revit and the viewer. Export to DWG, PDF, SVG and other formats from the viewer. Drawn at nominal real-world dimensions for layout and documentation; verify against local codes and the actual product before construction. Original Innerscene model, released CC0.

Looking for 3D parts and models? Browse the 3D Parts Library (10381).

Request a Drawing

If the library doesn’t have what you need, tell us. Requests decide what we add next. Leave an email and we’ll send you one message when it’s added.

Share Your Drawings

Have blocks, details or plans worth reusing? Upload DWG, DXF or PDF files, or a zip of them, and describe each one. Everything is reviewed before it appears, released under CC0, and kept for 1 to 5 years depending on file size. You can also add a single file from the viewer’s Share dialog. See the library terms.

Contribute drawings

Parts here are contributed by their authors or come from public-domain collections. If you believe a file infringes your rights, use Report on its viewer page or see our copyright policy.