Use this fixture in a lighting design

Open in CircadianLab to place this fixture in a room and calculate melanopic lux (EML), illuminance, UGR glare, and WELL v2 compliance — with radiosity simulation and real IES photometry. Free, no signup.

Open in CircadianLab
NORLYS••3 variants

NORLYS Stgockholm

297xx0010 99CRI

Select Variant

CRI 82
CRI 99
Lumens
806lm
Peak Candela
57cd
Power
9W
CCT
2,791K

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux806 lm
Peak Intensity57 cd
Input Power9 W
Correlated Color Temperature2,791 K
Color Rendering Index99
Symmetryfull
Lamp / SourcePhilips Master LEDbulb / Ledbulb Classic E27 8.5W
Catalog297xx0010 99CRI
Open in CircadianLabDownload IES FileIES file via NORLYS

About this Photometric File

This page presents the IES photometric distribution for the Stgockholm from NORLYS. This product line is published as 3 variants — typically different CCT and CRI combinations of the same luminaire optic. Use the variant selector above to switch between them.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the Stgockholm or any other NORLYS products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact NORLYS directly.

← Browse the full IES fixture library in CircadianLab