Juno Lighting(Acuity Brands)•Linear/Strip•6 variants

Juno Lighting Linear / SLW Linear — SM5_FR_SLW212_27K_80CRI

SM5 FR SLW212 27K 80CRI

Select Variant

CRI 80
CRI 95
Lumens
99lm
Peak Candela
32cd
Power
2W
Beam Angle
56°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux99 lm
Peak Intensity32 cd
Input Power2 W
Color Rendering Index80
Beam Angle (50% peak)56°
Symmetryquarter
Lamp / SourceSLW212 20FT 27K 80CRI (1 FT SECTION)
CatalogSM5 FR SLW212 27K 80CRI
Open in CircadianLabDownload IES FileIES file via cooperlighting.com

About this Photometric File

This page presents the IES photometric distribution for the Linear / SLW Linear — SM5_FR_SLW212_27K_80CRI from Juno Lighting, a Acuity Brands brand. This product line is published as 6 variants — typically different CCT and CRI combinations of the same luminaire optic. Use the variant selector above to switch between them.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the Linear / SLW Linear — SM5_FR_SLW212_27K_80CRI or any other Juno Lighting products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact Juno Lighting (Acuity Brands) directly.