Use this fixture in a lighting design

Open in CircadianLab to place this fixture in a room and calculate melanopic lux (EML), illuminance, UGR glare, and WELL v2 compliance — with radiosity simulation and real IES photometry. Free, no signup.

Open in CircadianLab
HALO(Cooper Lighting Solutions)•Downlight•3 variants

HALO HID / M200 — M200-26P_M100-C-U-MED

M200-26P

Select Variant

Lumens
8,800lm
Peak Candela
1,160cd
Power
115W
Beam Angle
115°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux8,800 lm
Peak Intensity1,160 cd
Input Power115 W
Beam Angle (50% peak)115°
Symmetryaxial
Lamp / SourceLU100/D/MED 100 WATTS 8800 LUMENS
CatalogM200-26P
Open in CircadianLabDownload IES FileIES file via cooperlighting.com

About this Photometric File

This page presents the IES photometric distribution for the HID / M200 — M200-26P_M100-C-U-MED from HALO, a Cooper Lighting Solutions brand. This product line is published as 3 variants — typically different CCT and CRI combinations of the same luminaire optic. Use the variant selector above to switch between them.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the HID / M200 — M200-26P_M100-C-U-MED or any other HALO products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact HALO (Cooper Lighting Solutions) directly.

← Browse the full IES fixture library in CircadianLab