Use this fixture in a lighting design

Open in CircadianLab to place this fixture in a room and calculate melanopic lux (EML), illuminance, UGR glare, and WELL v2 compliance — with radiosity simulation and real IES photometry. Free, no signup.

Open in CircadianLab
Franklite(Franklite Ltd.)•

Franklite WB125

WB125 82CRI

Lumens
139lm
Peak Candela
422cd
Power
3W
CCT
2,977K
Beam Angle
26°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux139 lm
Peak Intensity422 cd
Input Power3 W
Correlated Color Temperature2,977 K
Color Rendering Index82
Beam Angle (50% peak)26°
Symmetryfull
Lamp / SourceLED reading lamp
CatalogWB125 82CRI
Open in CircadianLabDownload IES FileIES file via Franklite

About this Photometric File

This page presents the IES photometric distribution for the WB125 from Franklite, a Franklite Ltd. brand.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the WB125 or any other Franklite products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact Franklite (Franklite Ltd.) directly.

← Browse the full IES fixture library in CircadianLab