Use this fixture in a lighting design

Open in CircadianLab to place this fixture in a room and calculate melanopic lux (EML), illuminance, UGR glare, and WELL v2 compliance — with radiosity simulation and real IES photometry. Free, no signup.

Open in CircadianLab
Fagerhult•

Fagerhult Notor 78 Delta 2400 direct elox 4K

13229-402

Lumens
6,000lm
Peak Candela
3,106cd
Power
54W
Beam Angle
90°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux6,000 lm
Peak Intensity3,106 cd
Input Power54 W
Beam Angle (50% peak)90°
Symmetryquarter
Lamp / SourceLED
Catalog13229-402
Open in CircadianLabDownload IES FileIES file via Fagerhult

About this Photometric File

This page presents the IES photometric distribution for the Notor 78 Delta 2400 direct elox 4K from Fagerhult.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the Notor 78 Delta 2400 direct elox 4K or any other Fagerhult products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact Fagerhult directly.