Delta Light(Delta Light NV)•

Delta Light iMAX II ADJUSTABLE TRIMLESS MP 92726 + iMAX II TUBE SQUARE TRIMLESS WHITE + iMAX II LINEAR SPREAD LENS

24215 9220 + 24213 0030 W + 24213 0070 90CRI

Lumens
1,458lm
Peak Candela
2,638cd
Power
14W
CCT
2,700K
Beam Angle
38°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux1,458 lm
Peak Intensity2,638 cd
Input Power14 W
Correlated Color Temperature2,700 K
Color Rendering Index90
Beam Angle (50% peak)38°
Symmetryfull
Lamp / SourceLed array @ 350mA
Catalog24215 9220 + 24213 0030 W + 24213 0070 90CRI
Open in CircadianLabDownload IES FileIES file via Delta Light

About this Photometric File

This page presents the IES photometric distribution for the iMAX II ADJUSTABLE TRIMLESS MP 92726 + iMAX II TUBE SQUARE TRIMLESS WHITE + iMAX II LINEAR SPREAD LENS from Delta Light, a Delta Light NV brand.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the iMAX II ADJUSTABLE TRIMLESS MP 92726 + iMAX II TUBE SQUARE TRIMLESS WHITE + iMAX II LINEAR SPREAD LENS or any other Delta Light products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact Delta Light (Delta Light NV) directly.

← Browse the full IES fixture library in CircadianLab