ATM Lighting(ATM LIGHTING)•

ATM Lighting INS390LED-1200-Y6-1 6850lm (YELLOW)

INS390LED-1200-Y6-1-35E-30-20P20-NIRO-GL 61CRI

Lumens
6,850lm
Peak Candela
2,720cd
Power
62W
CCT
1,800K
Beam Angle
102°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux6,850 lm
Peak Intensity2,720 cd
Input Power62 W
Correlated Color Temperature1,800 K
Color Rendering Index61
Beam Angle (50% peak)102°
Symmetryquarter
Lamp / SourceLED
CatalogINS390LED-1200-Y6-1-35E-30-20P20-NIRO-GL 61CRI
Open in CircadianLabDownload IES FileIES file via ATM Lighting

About this Photometric File

This page presents the IES photometric distribution for the INS390LED-1200-Y6-1 6850lm (YELLOW) from ATM Lighting, a ATM LIGHTING brand.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the INS390LED-1200-Y6-1 6850lm (YELLOW) or any other ATM Lighting products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact ATM Lighting (ATM LIGHTING) directly.

← Browse the full IES fixture library in CircadianLab