Use this fixture in a lighting design

Open in CircadianLab to place this fixture in a room and calculate melanopic lux (EML), illuminance, UGR glare, and WELL v2 compliance — with radiosity simulation and real IES photometry. Free, no signup.

Open in CircadianLab
Artemide•

Artemide PICTO 70 led Very Wide Flood

FTS1602982-A 90CRI

Lumens
1,877lm
Peak Candela
2,464cd
Power
20W
CCT
4,000K
Beam Angle
52°

Polar Plot (2D)

Loading photometric data…

Goniometer (3D)

Loading photometric data…

Beam Analysis

Loading photometric data…

Photometric Specifications

Total Luminous Flux1,877 lm
Peak Intensity2,464 cd
Input Power20 W
Correlated Color Temperature4,000 K
Color Rendering Index90
Beam Angle (50% peak)52°
Symmetryaxial
Lamp / SourceLED Flux=2108lm LED Power=17,5W Eff=89,04% EfcLed=120lm/W EfcLum=94lm/W Ra=90 SDCM=3 L70(6K)=60000h
CatalogFTS1602982-A 90CRI
Open in CircadianLabDownload IES FileIES file via Artemide

About this Photometric File

This page presents the IES photometric distribution for the PICTO 70 led Very Wide Flood from Artemide.

You can use this fixture in CircadianLab to design lighting layouts and calculate melanopic equivalent lux (EML), illuminance in lux or foot-candles, and UGR glare ratings — all in your browser, free, with no signup required.

Note on photometric plots: All plots on this page treat the luminaire as a point source emitting from its photometric center, which is the standard convention for IES LM-63 data.

Disclaimer: Innerscene does not manufacture, sell, or distribute the PICTO 70 led Very Wide Flood or any other Artemide products. This page is provided for informational and lighting-design purposes only, using publicly available photometric data. For product inquiries, pricing, or availability, please contact Artemide directly.