IESNA:LM-63-2002 [TEST]P295029 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-1808-918-20) [TESTLAB]INNOVATIONS CENTER(G3) [ISSUEDATE]12/2/2019 [MANUFAC] COOPER LIGHTING SOLUTIONS - METALUX (FORMERLY EATON) [LUMCAT]24CZ2-40HE-HRP-UNV-L940-CD1-U [LUMINAIRE]2'x4' TROFFER LED MODULE, HIGH EFFICIENCY ROUND PERF. LENS [LAMP](168) 4000K CCT, 90 CRI LEDS [DRIVER]ELECTRONIC DRIVER [_SEARCH_SOURCETYPE] LED [_SEARCH_CRI] 90 [_SEARCH_COLORTEMP] 4000K [_SEARCH_APPLICATION] Indoor, Ambient, Downlight, Wet Location, Residential [_SEARCH_MOUNTING] Surface [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]2674 TILT=NONE 168 -1 1 37 5 1 1 2 4 0 1 1 30.6 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 22.5 45 67.5 90 867.5 868.7 865.3 859.7 853 842.9 831.7 817.2 803.7 785.8 765.7 746.6 723.1 700.7 672.8 645.9 617.9 587.7 557.5 525 490.3 455.6 422 385.1 347 309 270.9 234 191.4 152.2 117.5 86.2 58.2 38.1 22.4 11.2 0 867.5 867.5 865.3 859.7 853 844 832.8 819.4 804.9 789.2 770.1 750 728.7 706.3 680.6 653.7 626.9 600 568.7 538.4 507.1 474.6 439.9 407.5 371.6 336.9 302.2 268.7 235.1 202.6 171.3 139.9 111.9 84 49.3 16.8 0 867.5 863.1 861.9 857.5 851.9 842.9 834 821.6 809.3 794.8 776.9 759 739.9 719.8 696.3 672.8 647 622.4 596.6 568.7 541.8 513.8 486.9 459 431 404.1 372.8 343.7 312.3 282.1 248.5 213.8 163.4 103 60.4 21.3 0 867.5 867.5 865.3 861.9 857.5 849.6 841.8 830.6 819.4 804.9 790.3 773.5 754.5 735.4 714.2 692.9 670.5 648.1 625.7 603.4 579.9 556.3 532.8 508.2 482.5 455.6 427.6 398.5 366 332.5 294.4 229.5 161.2 115.3 67.2 22.4 0 867.5 867.5 865.3 861.9 857.5 849.6 841.8 831.7 820.5 808.2 792.5 778 760.1 739.9 719.8 699.6 679.5 658.2 636.9 616.8 594.4 572 549.6 525 500.4 474.6 446.6 417.5 385.1 349.3 301.1 230.6 163.4 116.4 68.3 24.6 0