IESNA:LM-63-2002 [TEST]P295033 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-1808-918-20) [TESTLAB]INNOVATIONS CENTER(G3) [ISSUEDATE]12/2/2019 [MANUFAC] COOPER LIGHTING SOLUTIONS - METALUX (FORMERLY EATON) [LUMCAT]24CZ2-40-HRP-UNV-L940-CD1-U [LUMINAIRE]2'x4' TROFFER LED MODULE, HIGH EFFICIENCY ROUND PERF. LENS [LAMP](84) 4000K CCT, 90 CRI LEDS [DRIVER]ELECTRONIC DRIVER [_SEARCH_SOURCETYPE] LED [_SEARCH_CRI] 90 [_SEARCH_COLORTEMP] 4000K [_SEARCH_APPLICATION] Indoor, Ambient, Downlight, Wet Location, Residential [_SEARCH_MOUNTING] Surface [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]2785 TILT=NONE 84 -1 1 37 5 1 1 2 4 0 1 1 36.2 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 22.5 45 67.5 90 903.5 904.7 901.2 895.3 888.3 877.8 866.2 851 837 818.4 797.4 777.6 753.1 729.8 700.6 672.7 643.5 612 580.6 546.8 510.6 474.5 439.5 401 361.4 321.8 282.1 243.6 199.3 158.5 122.4 89.8 60.6 39.6 23.3 11.7 0 903.5 903.5 901.2 895.3 888.3 879 867.3 853.4 838.2 821.9 802.1 781.1 758.9 735.6 708.8 680.8 652.8 624.9 592.2 560.7 528.1 494.3 458.2 424.3 387 350.9 314.8 279.8 244.8 211 178.4 145.7 116.6 87.4 51.3 17.5 0 903.5 898.8 897.7 893 887.2 877.8 868.5 855.7 842.9 827.7 809.1 790.4 770.6 749.6 725.1 700.6 673.8 648.2 621.4 592.2 564.2 535.1 507.1 478 448.8 420.8 388.2 357.9 325.3 293.8 258.8 222.7 170.2 107.3 63 22.1 0 903.5 903.5 901.2 897.7 893 884.8 876.7 865 853.4 838.2 823 805.6 785.7 765.9 743.8 721.6 698.3 675 651.7 628.4 603.9 579.4 554.9 529.3 502.5 474.5 445.3 415 381.2 346.2 306.6 239 167.9 120.1 69.9 23.3 0 903.5 903.5 901.2 897.7 893 884.8 876.7 866.2 854.5 841.7 825.4 810.2 791.6 770.6 749.6 728.6 707.6 685.5 663.3 642.3 619 595.7 572.4 546.8 521.1 494.3 465.1 434.8 401 363.7 313.6 240.2 170.2 121.2 71.1 25.6 0