IESNA:LM-63-2002 [TEST]P295017 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-1808-918-20) [TESTLAB]INNOVATIONS CENTER(G3) [ISSUEDATE]12/2/2019 [MANUFAC] COOPER LIGHTING SOLUTIONS - METALUX (FORMERLY EATON) [LUMCAT]24CZ2-30-HRP-UNV-L940-CD1-U [LUMINAIRE]2'x4' TROFFER LED MODULE, HIGH EFFICIENCY ROUND PERF. LENS [LAMP](84) 4000K CCT, 90 CRI LEDS [DRIVER]ELECTRONIC DRIVER [_SEARCH_SOURCETYPE] LED [_SEARCH_CRI] 90 [_SEARCH_COLORTEMP] 4000K [_SEARCH_APPLICATION] Indoor, Ambient, Downlight, Wet Location, Residential [_SEARCH_MOUNTING] Surface [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]2012 TILT=NONE 84 -1 1 37 5 1 1 2 4 0 1 1 24.2 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 22.5 45 67.5 90 652.7 653.6 651 646.8 641.8 634.2 625.8 614.8 604.7 591.2 576.1 561.8 544.1 527.2 506.2 486 464.9 442.2 419.4 395 368.9 342.8 317.5 289.7 261.1 232.4 203.8 176 144 114.5 88.4 64.8 43.8 28.6 16.8 8.4 0 652.7 652.7 651 646.8 641.8 635 626.6 616.5 605.5 593.8 579.4 564.3 548.3 531.4 512.1 491.8 471.6 451.4 427.8 405.1 381.5 357.1 331 306.6 279.6 253.5 227.4 202.1 176.9 152.4 128.9 105.3 84.2 63.2 37.1 12.6 0 652.7 649.3 648.5 645.1 640.9 634.2 627.4 618.2 608.9 598 584.5 571 556.7 541.5 523.9 506.2 486.8 468.3 448.9 427.8 407.6 386.6 366.4 345.3 324.2 304 280.5 258.6 235 212.2 187 160.9 123 77.5 45.5 16 0 652.7 652.7 651 648.5 645.1 639.2 633.3 624.9 616.5 605.5 594.6 582 567.6 553.3 537.3 521.3 504.5 487.6 470.8 453.9 436.3 418.6 400.9 382.4 363 342.8 321.7 299.8 275.4 250.1 221.5 172.7 121.3 86.7 50.5 16.8 0 652.7 652.7 651 648.5 645.1 639.2 633.3 625.8 617.3 608.1 596.3 585.3 571.9 556.7 541.5 526.4 511.2 495.2 479.2 464.1 447.2 430.4 413.5 395 376.5 357.1 336 314.1 289.7 262.8 226.6 173.5 123 87.6 51.4 18.5 0