IESNA:LM-63-2002 [TEST]P990967 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G1-2503-387-30) [TESTLAB]Cooper Lighting Solutions [ISSUEDATE]5/13/2025 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML4ALSFLD2W1E-TIR4D25NFL-TL4RDSL-600LM-3000K [LUMINAIRE]4IN ROUND ML FLEX ADJUSTABLE, SELECTABLE CCT, WITH 25D TIR, METALLIC SILVER TRIM [LAMP](1) D2W LED 90CRI / 3000K CCT [_LIFETIME_TM21_2011]55000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]533 TILT=NONE 1 -1 1 49 1 1 1 -0.333333 -0.333333 0 1 1 8.3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 1287.5 1281.9 1268.9 1247.9 1220.7 1187.2 1147.6 1105.6 1057.9 1006.6 953.4 900.2 845.7 791.9 738.7 688 636 586.5 542.6 498.7 456.6 363.8 284.6 220.9 168.3 128.1 96.5 72.4 54.4 40.8 30.9 23.5 17.9 14.2 11.1 9.3 8 6.8 5.6 4.3 3.7 2.5 1.9 0.6 0.6 0 0 0 0