IESNA:LM-63-2002 [TEST]P886063 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-2402-314-73) [TESTLAB]COOPER LIGHTING SOLUTIONS [ISSUEDATE]7/18/2024 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML204LSFL95FS1E-TIR1D25NFL-TL2RDMB-170LM-4000K [LUMINAIRE]2IN ROUND ML FLEX, SELECTABLE CCT, WITH 25D TIR, MATTE BLACK TRIM [LAMP](1) HCL SELECTABLE LUMEN LED 95CRI / 4000K CCT [_LIFETIME_TM21_2011]55000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]146 TILT=NONE 1 -1 1 37 1 1 1 -0.166667 -0.166667 0 1 1 3.6 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 464.1 452.1 406.1 358.6 305.7 254.3 209.1 173.3 144.5 115.7 85.4 55.5 32.5 19.7 13.9 10.9 8.4 6.6 4 0.7 0.4 0.4 0.4 0 0 0 0 0 0 0 0 0 0 0 0 0 0