IESNA:LM-63-2002 [TEST]P885641 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-2402-314-119) [TESTLAB]COOPER LIGHTING SOLUTIONS [ISSUEDATE]7/18/2024 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML104LSFL95FS1E-TIR1D25NFL-TL1RDSL-340LM-4000K [LUMINAIRE]1IN ROUND ML FLEX, SELECTABLE CCT, WITH 25D TIR, METALLIC SILVER TRIM [LAMP](1) HCL SELECTABLE LUMEN LED 95CRI / 4000K CCT [_LIFETIME_TM21_2011]55000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]336 TILT=NONE 1 -1 1 37 1 1 1 -0.083333 -0.083333 0 1 1 6.1 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 1086.1 1056.6 954.5 840.7 718.5 579.4 454.1 345.5 254.9 179.1 123.3 88.5 69.5 57.9 49.5 43.2 36.9 30.6 22.1 16.9 14.7 12.6 10.5 8.4 7.4 5.3 4.2 3.2 2.1 2.1 1.1 1.1 1.1 0 0 0 0