IESNA:LM-63-2002 [TEST]P886511 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-2402-314-105) [TESTLAB]COOPER LIGHTING SOLUTIONS [ISSUEDATE]6/20/2024 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML204LSFLD2W1E-TIR1D55WFL-TL2SDSLB-400LM-4000K [LUMINAIRE]2IN SQUARE ML FLEX, SELECTABLE CCT, WITH 55D TIR, METALLIC SILVER BAFFLED TRIM [LAMP](1) D2W LED 90CRI / 3000K CCT [_LIFETIME_TM21_2011]55000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]444 TILT=NONE 1 -1 1 37 5 1 1 0.166667 0.166667 0 1 1 6.2 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 22.5 45 67.5 90 575.8 575 569.6 560.3 544.8 525.5 499.9 466.6 431 383.1 328.9 270.9 217.5 168.7 113.8 73.5 48 30.2 18.6 10.8 7 3.9 2.3 1.5 0.8 0.8 0.8 0.8 0.8 0.8 0 0 0 0 0 0 0 575.8 575 569.6 561.1 546.4 525.5 499.9 469 431 386.2 332 273.9 221.3 171.8 124.6 82.8 51.1 33.3 20.1 11.6 7 4.6 2.3 1.5 0.8 0.8 0.8 0.8 0 0 0 0 0 0 0 0 0 575.8 575 568.8 560.3 547.9 528.6 503 472.8 433.4 388.5 336.6 277.8 220.6 172.6 130.8 95.2 66.6 44.1 24.8 14.7 8.5 5.4 3.1 1.5 0.8 0.8 0.8 0.8 0 0 0 0 0 0 0 0 0 575.8 574.2 568.8 559.5 547.1 525.5 499.9 469 433.4 387.7 332.8 277 219.8 171 123.8 83.6 54.2 33.3 20.1 11.6 7 4.6 2.3 1.5 0.8 0.8 0.8 0.8 0 0 0 0 0 0 0 0 0 575.8 574.2 568.8 559.5 544 525.5 499.1 467.4 430.3 388.5 330.4 272.4 216.7 166.4 116.1 74.3 48.8 31 19.3 11.6 7 4.6 2.3 1.5 0.8 0.8 0.8 0.8 0.8 0.8 0 0 0 0 0 0 0