IESNA:LM-63-2002 [TEST]P990965 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G1-2503-387-29) [TESTLAB]Cooper Lighting Solutions [ISSUEDATE]5/13/2025 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML4ALSFLD2W1E-TIR4D25NFL-TL4RDMW-600LM-3000K [LUMINAIRE]4IN ROUND ML FLEX ADJUSTABLE, SELECTABLE CCT, WITH 25D TIR, MATTE WHITE TRIM [LAMP](1) D2W LED 90CRI / 3000K CCT [_LIFETIME_TM21_2011]55000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]526 TILT=NONE 1 -1 1 49 1 1 1 -0.333333 -0.333333 0 1 1 8.3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 1229.8 1224.8 1213.1 1193.3 1167.3 1137 1099.9 1059.7 1013.3 967.5 918.6 866 814.1 764 713.2 663.1 615.5 569.7 526.4 483.7 443.5 354.5 279 216.5 166.4 126.8 96.5 73.6 55.7 42.7 32.8 25.4 20.4 16.1 13.6 11.8 9.9 8.7 7.4 6.2 5.6 4.3 3.1 1.2 0.6 0.6 0 0 0