IESNA:LM-63-2002 [TEST]P358404 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G3-1908-462-19 - R2) [TESTLAB]INNOVATION CENTER (G3) [ISSUEDATE]3/3/2020 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO (FORMERLY EATON) [LUMCAT]HL36AR13FL935ED010TL3R2GMW [LUMINAIRE]HL3 13W Round, Flood optic with conical trim, Lensed, Matte White [LAMP](1) 3500K CCT, 90 CRI LEDS [DRIVER]ELECTRONIC DRIVER [_SEARCH_SOURCETYPE] LED [_SEARCH_CRI] 90 [_SEARCH_COLORTEMP] 3500K [_SEARCH_APPLICATION] Indoor, Amusement, Ambient, Atrium, Hotel, Downlight, Wet Location, Residential, Retail, [_SEARCH_MOUNTING] Recessed [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]1074 TILT=NONE 1 -1 1 37 1 1 1 -0.270833 -0.270833 0 1 1 12.8 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 2562 2541.7 2479.8 2377.2 2220.5 2018.3 1759.9 1464.8 1147.5 850.5 588.3 385.1 248.7 159.6 100.6 62.9 39.7 24.2 14.5 9.7 5.8 4.8 3.9 2.9 2.9 1.9 1.9 1.9 1 1 1 1 0 0 0 0 0