IESNA:LM-63-2002 [TEST]P641724 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G1-2212-866-103) [TESTLAB]COOPER LIGHTING SOLUTIONS [ISSUEDATE]2/17/2023 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO [LUMCAT]ML5612LSVWFL97FS1E - 594TBZB - 900LM - 4000K [LUMINAIRE]ML56 RR, MILKY OPTIC, 5" TUSCON BRONZE GIMBAL TRIM [LAMP](1) HCL SELECTABLE LUMEN LED 90CRI / 4000K CCT [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]1322 TILT=NONE 1 -1 1 37 1 1 1 -0.416667 -0.416667 0 1 1 13.3 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 590.5 589.3 586.8 583.1 578.1 570.7 563.2 552.1 540.9 527.2 512.4 495 475.1 454.1 431.7 405.7 378.4 351.1 322.5 292.8 263 233.2 204.7 176.2 151.4 126.5 106.7 88.1 72 58.3 47.1 36 27.3 19.8 13.6 8.7 0