IESNA:LM-63-2002 [TEST]P845437 [MORE]TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G2-2404-355-1) [TESTLAB]COOPER LIGHTING SOLUTIONS [ISSUEDATE]6/13/2024 [MANUFAC] COOPER LIGHTING SOLUTIONS - HALO TRACK [LUMCAT]L80815ECPKSP930MB [LUMINAIRE]HALO TRACK, 3000K, WITH 17D OPTIC [LAMP] (1) HIGH LUMEN LED 90CRI / 3000K CCT [_LIFETIME_TM21_2011]60000 [_LIFETIME PERCENTAGE]L70(10000) [_DRIVER]ELECTRONIC DRIVER [_MOUNTING]RECESSED [_ABSOLUTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED [MORE]ABSOLUTE PHOTOMETRY IS BASED ON CALIBRATION FACTORS [MORE]CREATED USING LAB LUMEN STANDARDS IN GONIOPHOTOMETER [MORE]WITH TEST DISTANCE OF 28.75 FEET [_ABSOLUTELUMENS]1553 TILT=NONE 1 -1 1 43 1 1 1 -0.208333 -0.208333 0 1 1 12.3 0 1 2 3 4 5 6 7 8 9 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 6857.3 6840.3 6752.3 6606.3 6364.3 5954.2 5391.2 4750.2 4120.2 3600.1 3194.1 2486.1 1961.1 1557.1 1247.1 1012 865 707 497 298 148 80 46 26 14 9 7 5 4 4 4 4 3 3 2 1 1 1 1 0 0 0 0